Search
Menu
Hamamatsu Corp. - Earth Innovations LB 2/24

Image Quality Testing Improves as Cameras Advance

Facebook X LinkedIn Email
Daniel Winters, TriOptics GmbH

An overview of state-of-the-art technology for image quality testing of mass-produced camera modules for consumer devices, including recent developments and new challenges.

Image quality testing of complete cameras and assembled camera modules is standard in the optics industry. It is done by imaging a suitable target using the camera module under test and evaluating the quality of the reproduction of the target. But recent rapid advances in consumer-type technology – for example, 13-MP-resolution cameras in smartphones becoming standard in the higher-priced region – are rewriting the rules. Therefore, new approaches for testing methodologies are required to keep up with the technological developments and economic pressure. Most of these can also be used in a similar fashion for all other camera testing applications, from high-end scientific to thermal imaging surveillance cameras.

Most consumer-type camera modules are integrated into devices such as smartphones and webcams and use relatively short-focal-length (1 to 5 mm), wide-field-of-view optics and either CCD or CMOS color sensors.

The parameters typically extracted during testing of such a module can broadly be classified into five categories: image quality via the modulation transfer function1 or the spatial frequency response2; properties of the optical system (e.g., distortion, relative illumination); optomechanical properties (e.g., relative alignment of the optics and the sensor or autofocus precision); color properties (e.g., color rendition, white balance); and sensor properties (e.g., dynamic range, linearity, noise, bad pixels). For modules incorporating flash capabilities, the alignment, illumination profile and intensity of the flash unit can be characterized as well. We will focus on the first three topics and discuss the remaining parameters only briefly.

Although most camera modules are designed to be used with the object at a larger distance (infinite conjugate), conventional testing techniques usually place a test target with various patterns – typically a test chart – at a shorter distance (finite conjugate) from the module.

‘Classical’ finite testing

The industry has come a long way since the first images taken from early test charts, similar to the more modern one in the ISO 12233 standard,2 which were originally designed to allow a human observer to judge image quality from that displayed on an analog TV monitor, for example. Today, testing with test charts in finite distance is standard, done by image analysis software in real time.

Figure 1 shows a schematic representation of a test chart system in finite configuration. The device under test (DUT) is placed in front of an illuminated chart with different markers and patterns on it. An image is then taken with the DUT, and software algorithms analyze the position and shape of the markers, and extract the performance parameters of the camera module.


Figure 1.
Typical finite distance test chart setup with the illuminated test chart placed at a finite distance from the device under test (DUT). Images courtesy of Trioptics GmbH.


A modified version of this setup incorporates a relay lens in between sample and chart to create a virtual image of the chart as seen from infinite distance. This approach usually requires a custom, high-quality relay lens, especially for larger-field-of-view applications and broadband (e.g., daylight) illumination, which can make such a setup complex and commercially unviable. This solution should be used only if infinity conjugate measurement and a more complex chart evaluation are required.

This test chart technology is relatively easy to deploy and combines a high density of measurement points with the ability to use different types of markers and patterns on different field positions of a single chart. It is typically used for sensor resolutions of up to 13 MP and testing in finite or close-to-infinite distances. However, because of recent advances in manufacturing technology, this technology reaches its limits as the industry moves to sensor resolutions of 13 MP and higher, which tightens the requirements on optics and the alignment of the individual components of the module.

Common precision and repeatability bottlenecks include the need for high homogeneity of the illumination over a large area, edge contrast and precision of the patterns on the test charts, and the required reproducible spectral distribution lighting, which is usually done with LEDs.

The size of the test instrument is another important factor in a production environment: For the wide-angle, large-field-of-view optics typically found in consumer camera modules, a large test chart is required. The larger the angular field of view, the larger the test chart must be for a given finite object distance, which cannot be set too small for infinity-set fixed-focus objectives. The situation is similar for modules that have a focusing capability – in this case, shorter object distances can be used but the setup does not properly reflect the final application. For large test charts, the corresponding large instrument requires more precious factory floor space.

Testing using collimator domes

An alternative approach for testing camera modules with larger object distances between about 1 m and infinity is to use a set of collimators as target projectors where each measurement point on the image sensor is provided by a dedicated collimator. A collimator consists of an illuminated target structure (the reticle) in the focal plane of an objective lens. The collimator projects the target virtually onto the DUT (Figure 2). The collimators can be either fixed-focus with preset infinity or finite object distances, or they can be motorized for variable object distances.

DataRay Inc. - ISO 11146-Compliant


Figure 2.
Collimator-based setup with the target being projected from a user-selectable distance of –1 m to infinity to 1 m onto the DUT. A simpler version uses fixed-focus collimators set to a specific distance; e.g., infinity.


The collimators are arranged in space so that the optical axes meet at the entrance pupil of the DUT. Different off-axis angles then correspond to different image positions on the DUT sensor, with on-axis being the center position on the sensor.

Although this setup is more complex than a test chart setup, it offers several advantages and higher flexibility for testing at different object distances:

• It can be used as a “true” infinite setup, with the DUT being tested under the same conditions as in the final application. This setup is quite insensitive to the actual positioning of the collimators, as the field positions are determined only by the angles between the collimators.

• The test chamber is compact, with the outer dimensions independent of the DUT field of view, so it uses less factory floor and is easier to manage. In fact, the mechanically closest distance of the collimators should be used.

• It is less sensitive to stray light, and the reticle illumination can be better controlled – which, in turn, leads to better repeatability.

• By using motorized collimators that can be focused, arbitrary object distances from approximately 1 m to infinity can be generated. This makes it possible to test the focusing of fixed- and autofocus modules. It is further important for the high-precision active alignment technology.

Figure 3 shows a typical collimator arrangement with nine collimators, all pointing into the entrance pupil of the DUT below (not shown). The spherical dome support allows the adjustment of the collimators to different object angles.


Figure 3.
Photograph of a collimator arrangement with nine collimators in a dome configuration. The DUT (not shown) is located below the collimators.


Additional tests: Business as usual

Besides the setups for measurement of image quality and optomechanical parameters discussed, other parameters are typically characterized for camera modules: These relate to color (e.g., white balance, color rendition3); sensor characteristics (linearity, sensitivity, bad pixels, etc.); or additional optical parameters such as distortion4 or veiling glare.5 Unfortunately, because of space constraints, they cannot be covered here in detail, but in general, the testing of these parameters is straightforward and well documented in the relevant standards.


Figure 4.
A schematic setup of 6-axis active-alignment setup using a computer-controlled movement platform (e.g., a hexapod) and a collimator dome as described in the text for fully automated alignment of sensor and optics, with optional glue dispensing and curing.


The image acquisition and transfer time for most camera modules is short, so the data obtained from the DUT also can be used in production to proactively and automatically align the optics and sensor to each other in a real-time, closed-loop process so that the combination delivers the highest possible performance. Besides the simple three-axis alignment for focusing (Z) and centering (X-Y) of the sensor, rotation and, especially, sensor tilt relative to the image plane of the optics can be adjusted (Figure 4). The tilt adjustment becomes increasingly important for high-performance, high-resolution modules with short depth of focus to reach the required image quality. As sensor resolution increases and the required tolerances become smaller, the industry is forced to use automatic alignment systems instead of further reducing manufacturing tolerances.

Depending on the application, either a collimator arrangement or a finite test chart is used to provide the required information for the multiaxis active alignment system. To fix the achieved camera alignment, a glue dispenser with UV light curing can be embedded into the system, making the instrument a fully automated fabrication station for camera modules.

Meet the author

Dr. Daniel Winters is head of the image quality testing R&D group at Trioptics GmbH in Wedel, Germany; email: [email protected].

References

1. T.L. Williams (1999). The optical transfer function of imaging systems. Institute of Physics Publishing.

2. ISO (2000). ISO standard 12233:2000: Photography – electronic still-picture cameras – resolution measurements.

3. ISO (2012). ISO standard 7321-1:2012: Colour characterisation of digital still cameras (DSCs). ISO 17321-1:2012: Graphic technology and photography – colour characterisation of digital still cameras (DSCs), Part 1: Stimuli, metrology and test procedures.

4. ISO (2008). ISO standard 9039:2008: Quality evaluation of optical systems – determination of distortion.

5. ISO (1994). ISO standard 9358:1994: Veiling glare of image forming systems.

Published: January 2014
Glossary
metrology
Metrology is the science and practice of measurement. It encompasses the theoretical and practical aspects of measurement, including the development of measurement standards, techniques, and instruments, as well as the application of measurement principles in various fields. The primary objectives of metrology are to ensure accuracy, reliability, and consistency in measurements and to establish traceability to recognized standards. Metrology plays a crucial role in science, industry,...
camera modulescamerasCCDCMOSConsumerFeaturesImagingmetrologyqualitySensors & DetectorsTest & MeasurementTrioptics GmbHcollimator domesDaniel Winters

We use cookies to improve user experience and analyze our website traffic as stated in our Privacy Policy. By using this website, you agree to the use of cookies unless you have disabled them.