Register
Sign In
Suppliers
Products
Categories
Handbook
Dictionary
Careers
Resources
Photonics Spectra
BioPhotonics
Vision Spectra
Virtual Events & Summits
Educational Institutions
Add/Update Your Listing
Exhibitor Listing Portal
Become an Exhibitor
Buyers' Guide Print Edition
Subscribe
Advertise
Suppliers
Products
Categories
Handbook
Dictionary
Careers
Resources
Photonics Spectra
BioPhotonics
Vision Spectra
Virtual Events & Summits
Educational Institutions
Add/Update Your Listing
Exhibitor Listing Portal
Become an Exhibitor
Buyers' Guide Print Edition
Register
Sign In
Photonics Marketplace
Suppliers
Products
Handbook
Institutions
Dictionary
Show Filters
Hide Filters
Products by Category
All Categories
Cameras & Imaging
Optics & Optical Fabrication
Illumination
Lasers
Spectroscopy
Coatings & Materials
Fiber Optics
Sensing & Detection
Optomechanics & Positioning
Microscopy
Software
49 products
Photonics Products
Clear All Filters x
probes x
M150XY(/M)
Thorlabs Inc.
Type:
Linear Stage
Max. Load:
10kg
Mass:
8.9kg
Height:
70.1mm
X-Axis Travel Length:
150mm
Y-Axis Travel Length:
150mm
Max. Linear Speed:
170mm/s
Absolute On-Axis Accuracy:
±10 μm
Continuous Motor Force:
10.0 N
Maximum Acceleration:
1000 mm/s^2
Microscopy Temperature Control System
Boston Electronics Corp.
Type:
Equipment
FRED Optical Engineering software
Photon Engineering LLC
Type:
Optical Design
NanoGetters Technology
Materion Balzers Optics
Type:
Filter Coatings
MEMS:
MultiMode 8-HR
Bruker Nano Surfaces
Type:
Scanning Probe
Imaging Noise Level:
<30 pm rms
Maximum Sample Size:
15 mm dia × 5 mm thick
JPK NanoWizard AFMs
Bruker Nano Surfaces
Type:
Scanning Probe
Innova
Bruker Nano Surfaces
Type:
Scanning Probe
Closed-Loop, Large-Area Scanner:
XY >90 µm, Z >7.5 µm
Open-Loop, Small-Area Scanner:
XY >5 µm, Z >1.5 µm
Sample Size:
45 mm × 45 mm x 18 mm
Dimension FastScan Bio
Bruker Nano Surfaces
Type:
Scanning Probe
Sample Environment — Flow Cell:
60 μL
X-Y Tip-Velocity Max.:
>2 mm/s
Z Range:
≥3 μm
Dimension FastScan
Bruker Nano Surfaces
Type:
Scanning Probe
Integral Nonlinearity XYZ:
<0.50%
X-Y Scan Range:
90 μm × 90 μm typical
Z Range:
10 μm typical in imaging
Dimension Edge
Bruker Nano Surfaces
Type:
Scanning Probe
X-Y Scan Range:
85 μm minimum
Z Range:
9.5 μm minimum
Ultima Multiphoton
Bruker Nano Surfaces
Type:
Scanning Probe
Scan Size:
64 x 64 to 2048 x 2048
Scanning Method:
Pair of 6mm galvanometers
Dimension Icon
Bruker Nano Surfaces
Type:
Scanning Probe
Integral nonlinearity XYZ:
<0.5% typical
X-Y scan range:
90 μm x 90 μm typical
Z range:
10 μm typical in imaging
Reflection & Fluorescence Fiber Optic Probes
art photonics GmbH
Type:
Equipment
Operating Temperature:
-70 °C to +200 °C
Pressure:
10 Bar
Wavelength Range (UV/VIS):
190-1300 nm
ATR Probes for FTIR Process Spectroscopy
art photonics GmbH
Type:
Equipment
1.1 to 17:
µ
-150 to +250:
°C
6.3 mm to 12 mm:
DIA
NTC Thermistor Temperature Probes
Amwei Thermistor Sensor Co. Ltd.
Type:
Equipment
PCBPN013-WG
Opto Engineering S.p.A.
Type:
Lenses
Diameter / Dimension:
7mm
Lens Category:
Other
Detector Type:
1/3"
Min FoV (diam × height):
25 × 15 mm
Min FoV (diam × height):
8.0 × 4.4 mm
enVISTA
Magnitude Instruments
Type:
Benchtop
Measurement Techniques:
Absorption,Emission,Fluorescence,Reflectance and Transmission,Other
Excitation Wavelength (nm):
0
Spectral Range (nm):
300 - 1050
Max. Resolution (nm):
1
Width:
67.3cm
Length:
59cm
Detection Limit:
10^-7 Absorbance Change
Excitation Rep-Rate:
8 Hz - 19 kHz
Sample Compartment Size:
25 cm × 25 cm
ProbePro Mini
Timegate Instruments Ltd.
Type:
Equipment
Diameter:
35 mm
Length:
175 mm
Microprobe
Timegate Instruments Ltd.
Type:
Equipment
SampleCube
Timegate Instruments Ltd.
Type:
Equipment
Light Aligner
SPECTROLIGHT Inc.
Type:
Optical Posts
508PV Microscope Spectrophotometer
CRAIC Technologies
Type:
Benchtop
Measurement Techniques:
Absorption,Emission,Fluorescence,Reflectance and Transmission
Spectral Range (nm):
200 - 2100
Max. Resolution (nm):
1
iBeam Smart
TOPTICA Photonics Inc.
Type:
Diode
Max. Power:
450mW
Classification (IEC):
Class 3B
Wavelength:
375 - 1060nm
Wavelength - Tunable?:
No
Operating Mode:
Continuous
enVISion
Magnitude Instruments
Type:
Benchtop
Measurement Techniques:
Absorption,Emission,Fluorescence,Reflectance and Transmission,Other
Spectral Range (nm):
300 - 2500
Max. Resolution (nm):
1
Width:
116cm
Length:
66cm
Height:
33cm
Detection Limit:
10^-7 Absorbance Change
Excitation Rep-Rate:
8 Hz - 19 kHz
Sample Compartment Size:
25 cm × 25 cm
dbOptic
Sky Scientific
Type:
Optical Design
PRONTO-250 Portable Laser Power Meter
Gentec Electro-Optics Inc.
Type:
Portable
Wavelength Range:
0.193 - 20µm
Measure Power?:
Yes
Max. Measurable Power:
250W
Aperture Diameter:
19 mm
Exposure Time:
5 s
Maximum Average Power Density:
45 kW/cm²
ATR Fiber Probe for hazardous environments
art photonics GmbH
Type:
Component
Industrial application:
12 mm diam shaft
Lab application:
6 m diam shaft
TS Series Temperature Sensors
Micronor Sensors Inc.
Type:
Equipment
Accuracy:
0.2 °C
Measurement Range:
-200 °C to +300 °C
Resolution:
0.1 °C
Model 100 UV Light Meter
G & R Labs Inc.
Type:
Equipment
NIST Traceability:
±3.0%
Range:
.01 MW/CM2 to 199.99 MW/CM2 or .1 MW/CM2 to 1999.9 MW/CM2
Model 220 UV Light Meter
G & R Labs Inc.
Type:
Equipment
Instrument:
Scientific
NIST Traceable:
+/-3%
Probes:
Interchangeable
PVRS 2-305-1000
USA Borescopes
Type:
Equipment
DWS RheoLab
LS Instruments AG
Type:
Equipment
Complex Modulus G*:
1-50 kPa
Frequency:
0.1 Hz-10 MHz
Sample Volume:
150-1500 uL
Copper Tube NTC Thermistor
Amwei Thermistor Sensor Co. Ltd.
Type:
Equipment
Resistance @25 °C:
10K ohm
PTC Thermistor Heater Assembly
Amwei Thermistor Sensor Co. Ltd.
Type:
Equipment
Inrush Current:
0.8 - 1.5 A
Operating Voltage:
12 - 24 V
Power (Watts):
14 W
Rivet NTC Thermistor Temperature Probe
Amwei Thermistor Sensor Co. Ltd.
Type:
Equipment
PTC Thermistor
Amwei Thermistor Sensor Co. Ltd.
Type:
Equipment
Reference Temp.:
80 °C, 100 °C, 120 °C
Resistance @25 °C:
70 ohm - 4700 ohm
Withstanding Voltage:
420 - 1000 V
XUV-18
Star Tech Instruments Inc.
Type:
Other
Sensor Width:
25
Light Spectrum:
XRAY,UV
Calibration:
NIST
High Damage Threshold:
5 W/ cm2
Interface:
Bluetooth, WiFi, BNC
FS-70 Series 378-Microscope Unit
Mitutoyo America Corp.
Type:
Optical
Magnification:
20X
Spectral Range:
VIS
TERA K15
Menlo Systems Inc.
Type:
Portable
Measurement Techniques:
Absorption,Reflectance and Transmission
Width:
900mm
Length:
600mm
Height:
200mm
Weight (kg):
34
Dynamic range:
>90 dB (typ. 95 dB)
Laser ports:
1560 nm, alternat. 780 nm
Laser repetition rate:
100 MHz
Vividia ME-610 Industrial Automotive Videoscope Borescope
Oasis Scientific Inc.
Type:
Optical
Magnification:
4X
Angle of Field:
100 degree
LED Lights:
6 pcs
Monitor Size:
3.5 inch
µXUV
Star Tech Instruments Inc.
Type:
Portable
Beam Diameter:
25mm
Wavelength Range:
1 - 200nm
Measure Power?:
Yes
Max. Measurable Power:
5W
Calibration:
NIST
High Damage Threshold:
5 W/ cm2
Vacuum:
10-9 torr
Active Cantilever Scanning Microscope
Seiwa Optical America Inc.
Type:
Scanning Probe
BREVA Hexapod
Symetrie
Type:
Hexapod
Max. Load:
200kg
Mass:
36kg
Height:
350cm
X-Axis Range:
75mm
Y-Axis Range:
75mm
Z-Axis Range:
50mm
Repeatability Rx, Ry, Rz:
± 5 µrad
Repeatability Tx, Ty, Tz:
± 1 µm
Resolution Rx, Ry, Rz:
2.5 µrad
BEM Series- Energy Probe for Excimer Lasers
Star Tech Instruments Inc.
Type:
Post Mounted
Max. Measurable Energy:
0.6J
Beam Diameter:
38mm
Wavelength Range:
157 - 405nm
Max. Frequency:
5000Hz
Measure Power?:
Yes
Max. Measurable Power:
5W
VHR Series- Low Insertion, Loss Energy Probe
Star Tech Instruments Inc.
Type:
Portable
Max. Measurable Energy:
0.6
Beam Diameter:
50mm
Wavelength Range:
2 - 405nm
Max. Frequency:
5000Hz
Measure Power?:
Yes
Max. Measurable Power:
5W
Beam Sizes:
to 50 mm diam
Damage Threshold:
0.6 J/cm2
Vacuum compatibility:
to 10-8 Torr
SFS - Cube
LDI Innovation OU
Type:
Portable
Measurement Techniques:
Fluorescence
Excitation Wavelength (nm):
220
Spectral Range (nm):
220 - 700
Max. Resolution (nm):
5
Pixel Count (total pixels):
256
Width:
300mm
Connection Type:
WiFi
Detector Type:
PMT
Light Source:
Xe lamp
SR-6500
Spectral Evolution Inc.
Type:
Portable
Measurement Techniques:
Absorption,Reflectance and Transmission
Spectral Range (nm):
350 - 2500
Max. Resolution (nm):
1.5
Width:
22.9cm
Length:
38.7cm
Height:
31.5cm
Piezoelectric Stage XY25XS
Cedrat Technologies SA
Type:
Nanopositioning Stage
Mass:
80g
Stage Type:
Motorized
Driver Included?:
No
Blocked Force:
40 N
Stiffness:
2.50 N/µm
Unloaded Resonance Freq.:
3000 HZ
Planar ServoRIng PSR-200
IntelLiDrives Inc.
Type:
Rotation Stage
Max. Load:
50kg
Mass:
7kg
Height:
42mm
Max. Rotation Speed (degrees/s):
300
Stage Type:
Motorized
Driver Included?:
Yes
Continuous current:
5.1 amp
Resolution:
0.5 arc-sec
Tabletop diam:
200 mm
Photonics Products
Explore Our Content
News
Features
Latest Products
Webinars
White Papers
All Things Photonics Podcast
Videos
Our Summits & Conferences
Industry Events
Bookstore
Join Our Community
Subscribe
Advertise
Become a member
Sign in
Contribute a Feature
Suggest a Webinar
Submit a Press Release
Mobile Apps
About Us
Our Company
Our Publications
Contact Us
Career Opportunities
Teddi C. Laurin Scholarship
Terms & Conditions
Privacy Policy
California Consumer Privacy Act (CCPA)
©2024 Photonics Media
100 West St.
Pittsfield, MA, 01201 USA
[email protected]
We use cookies to improve user experience and analyze our website traffic as stated in our
Privacy Policy
. By using this website, you agree to the use of
cookies
unless you have disabled them.