Spotting a single cancerous cell that has broken free from a tumor and is traveling through the bloodstream to colonize a new organ might seem like finding a needle in a haystack, but a new imaging technique from the University of Washington (UW) is a first step toward making this possible.

UW researchers have developed a multifunctional nanoparticle that eliminates the background noise, enabling a more precise form of medical imaging – essentially erasing the haystack, so the needle shines through. A successful demonstration with photoacoustic imaging was reported recently in the journal Nature Communications.


On top are photoacoustic images taken for gold nanorods (left), the new UW particle that has a magnetic core and surrounding gold shell (center), and a simple magnetic nanoparticle (right). Below is the same image after processing to remove pixels not vibrating with the magnetic field. The center blob is retained because of the particles’ magnetic core and is bright because of the particles’ gold shell. (Images: Xiaohu Gao, University of Washington)

Nanoparticles are promising contrast agents for ultrasensitive medical imaging. But in all techniques that do not use radioactive tracers, the surrounding tissues tend to overwhelm weak signals, preventing researchers from detecting just one or a few cells.

“Although the tissues are not nearly as effective at generating a signal as the contrast agent, the quantity of the tissue is much greater than the quantity of the contrast agent and so the background signal is very high,” said lead author Xiaohu Gao, a UW assistant professor of bioengineering.


An external magnetic field attracts the nanoparticles by their magnetic cores. When the field is turned off, the tissue relaxes and the particles return to their initial positions.


The newly presented nanoparticle solves this problem by combining two properties to create an image that is different from what any existing technique could have produced. The new particle combines magnetic properties and photoacoustic imaging to erase the background noise. Researchers used a pulsing magnetic field to shake the nanoparticles by their magnetic cores. Then they took a photoacoustic image and used image-processing techniques to remove everything except the vibrating pixels.

Gao compares the new technique to “Tourist Remover” photo editing software that allows a photographer to delete other people by combining several photos of the same scene and keeping only the parts of the image that aren’t moving. “We are using a very similar strategy,” Gao said. “Instead of keeping the stationary parts, we only keep the moving part.”

Rocky Mountain Instruments - Infrared Optics MR

“We use an external magnetic field to shake the particles,” he added. “Then there’s only one type of particle that will shake at the frequency of our magnetic field, which is our own particle.”

Experiments with synthetic tissue showed the technique can almost completely suppress a strong background signal. Future work will try to duplicate the results in lab animals, Gao said.

The 30-nm particle consists of an iron-oxide magnetic core with a thin gold shell that surrounds – but does not touch – the center. The shell absorbs infrared light, and could also be used for optical imaging, delivering heat therapy, or attaching a biomolecule that would grab on to specific cells.

Earlier work by Gao’s group combined functions in a single nanoparticle, something that is difficult because of the small size.


The 30-nm particle consists of a magnetic core and a thin gold shell, analogous to an eggshell, that surrounds but does not touch the center.

“In nanoparticles, one plus one is often less than two,” Gao said. “Our previous work showed that one plus one can be equal to two. This paper shows that one plus one is, finally, greater than two.”

The first biological imaging, in the 1950s, was used to identify anatomy inside the body, detecting tumors or fetuses. The second generation has been used to monitor function –functional magnetic resonance imaging (fMRI), for example, detects oxygen use in the brain to produce a picture of brain activity. The next generation of imaging will be molecular imaging, said Gao’s colleague, Matthew O’Donnell, a UW professor of bioengineering.

This will mean that medical assays and cell counts can be done inside the body. In other words, instead of taking a biopsy and inspecting tissue under a microscope, imaging could detect specific proteins or abnormal activity at the source.

But making this happen means improving the confidence limits of the imaging.

“Today, we can use biomarkers to see where there’s a large collection of diseased cells,” O’Donnell said. “This new technique could get you down to a very precise level – potentially of a single cell.”

Researchers tested the method for photoacoustic imaging, a low-cost method now being developed that is sensitive to slight variations in tissues’ properties and can penetrate several centimeters in soft tissue. It works by using a pulse of laser light to heat a cell very slightly. This heat causes the cell to vibrate and produce ultrasound waves that travel through the tissue to the body’s surface.

For more information, visit:  www.uw.edu 



Published: August 2010
Glossary
infrared
Infrared (IR) refers to the region of the electromagnetic spectrum with wavelengths longer than those of visible light, but shorter than those of microwaves. The infrared spectrum spans wavelengths roughly between 700 nanometers (nm) and 1 millimeter (mm). It is divided into three main subcategories: Near-infrared (NIR): Wavelengths from approximately 700 nm to 1.4 micrometers (µm). Near-infrared light is often used in telecommunications, as well as in various imaging and sensing...
nano
An SI prefix meaning one billionth (10-9). Nano can also be used to indicate the study of atoms, molecules and other structures and particles on the nanometer scale. Nano-optics (also referred to as nanophotonics), for example, is the study of how light and light-matter interactions behave on the nanometer scale. See nanophotonics.
photoacoustic imaging
Abbreviated PAI. An imaging modality with a hybrid technique based on the acoustic detection of optical absorption from endogenous chromophores or exogenous contrast agents. Light is absorbed by the chromophores and converted into transient heating, and through thermoelastic expansion there is a resulting emission of ultrasonic waves. In tissue, ultrasound scatters less than light, therefore PAI generates high-resolution images in the diffusive and optical ballistic regimes compared to purely...
Americasbackground noiseBiophotonicscancercell biologyCommunicationscontrast agentsgoldImaginginfrarediron oxidemagnetic fieldsMatthew O’Donnellmedical imagingMicroscopynanonanoparticlesNature Communicationsphotoacoustic imagingResearch & TechnologySeattletumors University of WashingtonXiaohu Gao

We use cookies to improve user experience and analyze our website traffic as stated in our Privacy Policy. By using this website, you agree to the use of cookies unless you have disabled them.