Signal Sorting Method Suppresses Noise in STED Microscopy

Facebook X LinkedIn Email
Researchers from Zhejiang University have proposed a novel microscopy method that selectively and effectively suppresses background noise in the existing technique of stimulated emission depletion (STED) microscopy. The newly developed approach bypasses drawbacks that are caused by current methods used for noise suppression in STED imaging, which is considered a limitation of the technique.

STED microscopy was developed in 1994, demonstrated in 1999, and earned its developer, Stefan Hell, the Nobel Prize in chemistry in 2014. The practical use of STED microscopy, which is a superresolution technique to image beyond the capabilities of nanoscopy or the generally accepted optical limit of 200 to 300 nm, involves undesirable background noise that affects spatial resolution and image quality. In general, it comes from two signal sources: fluorescence generated by reexcitation caused by ultrahigh light doses from the depletion beam, and residual fluorescence due to insufficient depletion of the inhibition beam.

Though background removal approaches have been developed, limitations of their implementation range from image distortion to prolonged acquisition times, and/or the introduction of shot noise.

Existing methods for background removal approaches can be divided into the categories of time-domain, space-domain, and phasor-domain.

Researchers in China developed a frequency-domain STED microscopy method to selectively suppress the backgrounds in STED imaging. The method offers an improvement over existing noise suppression techniques that cause other issues with STED imaging performance. Courtesy of Longgang Mulin Graphics
Researchers in China developed a frequency-domain STED microscopy method to selectively suppress the backgrounds in STED imaging. The method offers an improvement over existing noise suppression techniques that cause other issues with STED imaging performance. Courtesy of Longgang Mulin Graphics.
The proposed method in the recent work is called “dual-modulation difference” STED (dmdSTED) microscopy. It works by sorting space-domain signals into the frequency domain so that the nondepleted fluorescence and STED-induced background are conveniently separated from the desired fluorescent signals. The excitation and the depletion beams are loaded respectively with different time-domain modulations.

Ohara Corp. - Optical Glass, Polish substrates 10-23

Since it avoids the re-excitation caused by the depletion beam, a depletion laser with a wavelength closer to the peak of the fluorescence emission spectrum of the sample can be selected, which reduces the required depletion intensity.

The current version of dmdSTED performs with spatial resolution of λ/8, which is higher resolution than that of the phasor-domain methods, which are prone to shot noise. Theoretically, the researchers said, the approach can help to avoid potential signal loss by time-domain approaches, such as time-gating.

In addition, dmdSTED is compatible with either pulsed or continuous-wave scenarios, and hardware for time-correlated single-photon counting is not required for use. Compared with space-domain methods, the time resolution of dmdSTED is not confined. As a result, dmdSTED is advantageous in the acquisition of comprehensively fine microscopy images, in spatial resolution, signal-to-noise ratio, and time resolution.

According to Xu Liu, director of the State Key Laboratory of Modern Optical Instrumentation and senior author of the study, the frequency domain method has the potential to be integrated into other dual-beam point-scanning techniques. These include excited state saturation microscopy, charge state depletion microscopy, and ground state depletion microscopy.

Further, Liu said, the method can accept more types of samples with spectral characteristics that differ from the fluorescent dyes that are commonly used in STED imaging. These include some quantum dots that may demonstrate wider excitation spectra.

The research was published in Advanced Photonics (www.doi.org/10.1117/1.AP.4.4.046001).

Published: July 2022
Glossary
sted microscopy
STED microscopy, or stimulated emission depletion microscopy, is a superresolution imaging technique in fluorescence microscopy that surpasses the diffraction limit, enabling the visualization of structures at the nanoscale level. This technique was developed to overcome the limitations imposed by the diffraction of light, which traditionally hindered the resolution of optical microscopy to a few hundred nanometers. Key features and principles of STED microscopy: Superresolution: STED...
noise
The unwanted and unpredictable fluctuations that distort a received signal and hence tend to obscure the desired message. Noise disturbances, which may be generated in the devices of a communications system or which may enter the system from the outside, limit the range of the system and place requirements on the signal power necessary to ensure good reception.
frequency domain
The frequency domain is a concept used in signal processing and analysis to represent signals and data in terms of their frequency components. In contrast to the time domain, where signals are described with respect to time, the frequency domain provides information about the frequency content of a signal. Here are key points related to the frequency domain: Frequency and time domains: Time domain and frequency domain are two different ways of representing the same information. A signal's...