Search
Menu

TOCS LED Measurement Systems

Labsphere Inc.Request Info
 
Facebook X LinkedIn Email
Labsphere Inc.'s TOCS (thermal/optical/electrical) LED measurement systems conform to IESNA LM-79 and LM-80 recommendations for LED characterization.

To more easily meet new reporting specifications, the systems enable measurement of optical properties as a function of temperature and operating current using a single instrument to deliver accurate and reproducible LED measurements.

Available in a range of integrating sphere sizes from 50.8 to 193 cm, the TOCS systems are designed for both 2pi and 4pi measurement geometries. A lamp measurement integrating sphere, a high-resolution CCD array spectrometer, a thermal plate with temperature controller, an auxiliary lamp, a calibration source, a power supply and proprietary TOCS-SS software comprise the basic system. Owners of current Labsphere and SphereOptics spectral lamp measurement systems may purchase an upgrade retrofit to the TOCS system to achieve LM-79 and LM-80 compliance.

The software automates procedures for measuring spectral characteristics and controlling current and temperature. Users control LED temperature and operating current at specified ranges, measuring and characterizing the device under test over a wide temperature range. The simultaneously collected electrical, optical and thermal data is graphed for quick on-screen viewing and can be exported to Excel format for in-depth analysis.

The systems can be customized with the integrating sphere size, calibration source and accessories to fit testing needs.



Published: August 2010
REQUEST INFO ABOUT THIS PRODUCT
* First Name:
* Last Name:
* Email Address:
* Company:
* Country:
Message:


When you click "Send Request", we will record and send your personal contact information to Labsphere Inc. by email so they may respond directly. You also agree that Photonics Media may contact you with information related to this inquiry, and that you have read and accept our Privacy Policy and Terms and Conditions of Use.

Register or login to auto-populate this form:
Login Register
* Required

2pi4piAmericasauxiliary lampcalibration sourceCCD array spectrometerelectricalExcelIESNA LM-79IESNA LM-80integrating sphereLabsphereLight Sourceson-screen viewingoperating currentopticalpower supplyProductsspectroscopytemperaturetemperature controllerTest & Measurementthermalthermal plateTOCSTOCS-SS softwareLEDs

We use cookies to improve user experience and analyze our website traffic as stated in our Privacy Policy. By using this website, you agree to the use of cookies unless you have disabled them.