By using a high-speed camera to study plumes created by a tunable infrared laser, researchers at Louisiana State University have revealed some of the mechanisms involved in material ablation. The plume study technique could someday result in better mass spectrometer performance, said research team leader and chemistry professor Kermit K. Murray, and that could help life sciences and materials research.

When studying biomolecules and other macromolecules, investigators frequently make use of matrix-assisted laser desorption ionization. In this method, a laser pulse ablates material, and a mass spectrometer samples the ions in the plume.


Shown is a plume captured 24 µs after a 2.94-µm laser shot struck glycerol. By studying how such plumes evolve over time, researchers can improve how much material is ionized and thus becomes suitable for mass spectrometry. Courtesy of Kermit K. Murray, Louisiana State University.
The problem is that most of the material removed is electrically neutral and, therefore, undetectable. “If we can adjust the ablation conditions to maximize the conversion of the sample into ions, we will improve the performance of the mass spectrometer,” Murray said.

In trying to understand just what is going on in a plume, researchers have long turned to high-speed photography. Murray and graduate student Xing Fan added a twist to this idea. They combined a fast camera with a tunable mid-infrared laser, constructing it from an optical parametric oscillator and an Nd:YAG laser from Continuum of Santa Clara, Calif. This setup allowed them to adjust the pulse wavelength from 1.4 to 4.0 µm and to study how that changed material removal.

PI Physik Instrumente - Revolution In Photonics Align LW MR3/24

In their experiments, the researchers fired 5-ns pulses from this mid-IR source into a glycerol sample sitting on a stainless steel target. For illumination, they used an excimer KrF laser from Lambda Physik of Göttingen, Germany, triggering it after the first laser shot. As a result, the 248-nm, 8-ns pulses from this second laser illuminated the plume at specific times. To capture the plume’s appearance, the duo used a CMOS digital camera from Vitana Co. of Ottawa.

Using this setup, they obtained one image per laser shot. Murray noted that an ideal camera would record a video from a single shot. However, the technology doesn’t yet exist to strobe and record images at the necessary speed, he said.

Thus, reconstructing the plume evolution required that the researchers take multiple shots. They did so for wavelengths from 2.7 to 3.5 µm, finding that the greatest material ablation and the longest plume duration took place near 3.0 µm. That, they noted in the Jan. 28, 2009, issue of Journal of Physical Chemistry, corresponds to the stretch absorption of OH, a molecular constituent of glycerol. Modeling calculations suggested that the material removal was driven by a stress-confined phase explosion.

Murray said that tuning the wavelength and energy will allow optimization of laser desorption mass spectrometry techniques, especially those performed under ambient conditions. Maximizing the laser’s effectiveness is important to various research areas, he said. “One of the most promising applications is tissue imaging, where the ability to remove the biomolecules from within the sample is critical to success.”

Published: March 2010
Glossary
high-speed photography
Photography involving the recording of events that occur too fast to be perceived by the human eye or recorded by conventional photographic techniques. See high-speed movie camera; high-speed shutter; high-speed still camera.
mass spectrometer
A device used to measure the masses and relative concentrations of atoms and molecules. It utilizes the Lorentz force generated by external magnetic field on a moving charged particle, in which the particles are deflected by the magnetic field according to their masses. Once deflected, the particles are detected and recorded electrically to provide a mass spectrum of the input beam of ions.
mass spectrometry
An instrumental technique that utilizes the mass-to-charge ratio of charged particles as recorded from a mass spectrometer in order to determine the mass of a particle as well as the chemical makeup, or elemental ionic composition of a given sample or molecule.
ablationBasic SciencebiomoleculesBiophotonicsCaliforniaCanadaCMOScontinuumGermanyglycerolHank HoganHank Hoganhigh-speed photographyhigh-speed camerahigh-speed photographyinfrared laserionsJournal of Physical ChemistryKermit K. MurrayKrFLambda Physiklaser pulselife sciencesLouisiana State UniversitymacromoleculesMaldimass spectrometermass spectrometrymaterials researchmatrix-assisted laser desorption ionizationNd:YAGOHplumesResearch & Technologyspectroscopystress-confined phase explosionTech PulseTest & MeasurementVitana Co.Xing FanLasers

We use cookies to improve user experience and analyze our website traffic as stated in our Privacy Policy. By using this website, you agree to the use of cookies unless you have disabled them.