Sound and Light, Signifying Improved Imaging

Facebook X LinkedIn Email
Lynn Savage, Features Editor, [email protected]

Pure light is good for many bioimaging studies, but it has insurmountable limitations when it comes to scanning beneath the surface of the skin. Light in the near-IR range of about 2 to 3 µm can penetrate tissue up to only 0.1 to 1 mm, far too shallow to search for anything more than subcutaneous evidence of healthy activity or disease. Wavelengths between 650 and 1300 nm can reach 1 to 2 mm before light scattering within the tissue reduces image resolution too much to be useful.

Sound waves, however, aren’t scattered nearly as much by a tissue’s cellular and water content as light is, leading some researchers to pursue ultrasound techniques to image living organisms. But where ultrasound has the desired penetrability, it does not offer the high resolution that purely light-based imaging does.

Unsurprisingly, then, the two technologies came together. Or, rather, they were pushed.

About 20 years ago, a scientist with ultrasound experience was looking at novel piezo-based transducers that might provide the higher frequencies and smaller scale he needed for better images and easier use. That search led Matthew O’Donnell, now dean of the college of engineering at the University of Washington in Seattle, to investigate photoacoustic techniques, in which light and sound work together. He hasn’t turned back, and many others have joined him.

In a typical photoacoustic setup, pulses of laser light shine on a target, which can be a photoreactive agent, a glistening nanoparticle or a natural substance such as hemoglobin. As the target absorbs the laser’s energy, part of its response is to emit an ultrasonic noise. The sound waves thus emitted are, in turn, detected by a nearby array of piezoelectric or fiber optic sensors and converted into images that can be read by the device’s operator.

With fairly high resolution and an ability to plumb relatively large depths into tissue – especially compared to infrared imaging – photoacoustic technology is useful for a number of imaging purposes. The technique is used to search for tumors and lesions, to investigate blood vessels and other parts of the vasculature, and to examine targets from whole animals down to individual cells.

Using photoacoustics to image blood vessels is particularly useful for studying the way cancer tumors feed and grow. And it is a useful tool for observing hemodynamics because it can differentiate between the total hemoglobin in blood and the hemoglobin that is saturated with oxygen.

Photoacoustics is also useful during patient therapy for procedures that include measuring temperature, and helping with placement of tubes and needles for drug delivery and biopsies, and with radioactive seeds for brachytherapy. Nonetheless, its main purpose is diagnostic and therapeutic imaging.

Where optical imaging and ultrasound imaging once were separated into two very distinct camps, according to O’Donnell, there has come a change in everyone’s approach.

“We are starting to see the integration of optics and ultrasound thinking,” he said. And new photoacoustic tools someday “will become the core part of everyday medical treatment.”

Needles and haystacks


Cancer metastases are a major cause of patient mortality. Tumors metastasize when individual cells break away from an active site and float down the bloodstream, adhere to another site and begin to generate a new tumor and supporting blood vessels. Traditional imaging techniques, such as computed tomography, can find these new tumors when they’ve grown to a few millimeters, but by then it is likely that the patient is well into the final stages of disease. Finding the breakaway tumor cells while they are still midstream would be a powerful tool to pinpoint – and perhaps challenge – metastasis. Several research groups have developed techniques for getting the job done.

John Viator, associate professor of bioengineering and dermatology at the University of Missouri in Columbia, is developing a photoacoustic flow cytometry method that can look for single cancer cells in blood samples. In a basic setup, blood flowing past a photoacoustic sensor is struck by laser light. Certain constituents of the blood, such as melanin, hemoglobin and tumor cells, emit a characteristic sound wave as a response to the light.

Viator’s group is focused on using the technique to look for circulating melanoma cells and has tested its photoacoustic system to train nanosecond-scale laser pulses on melanoma-laden white blood cells that have been extracted from whole blood. The irradiation of these samples causes a distinct high-frequency sonic response from the melanoma cells hidden among the white blood cells, according to the researchers. The group has since verified that even individual melanoma cells are detectable with the technique.

“Photoacoustics combines the selectivity of optical targeting with the sensitivity of ultrasonic signals,” Viator said.

Finding individual cancer cells, however, is not enough; you also must remove them before they start a new tumor.

Vladimir P. Zharov of the University of Arkansas at Little Rock has been performing pioneering work in photoacoustic flow cytometry advances during the past decade. Working in a broad range of applications, Zharov and his colleagues are studying the effects of labeling target cells with gold-coated carbon nanotubes, quantum dots or magnetic nanoparticles; exploring multicolor photoacoustic imaging; and testing laser systems that will increase the imaging speed and sensitivity of single-cell detection.

In studies of sentinel lymph nodes – often the first landing spot for stray cancer cells – Zharov’s group used a fiber-based laser system to detect and destroy melanoma cells. The system it used for this and most subsequent projects comprises an Olympus microscope; a tunable optical parametric oscillator made by Lotis Ltd. of Minsk, Belarus; a 905-nm diode laser manufactured by Frankfurt Laser Co. of Friedrichsdorf, Germany; and an ultrasound transducer made by Imasonic Inc. of Besançon, France.

The investigators used gold-coated carbon nanotubes as a contrast agent within the lymph system, gaining a second color, which aided identification of the lymph nodes and vessels by employing magnetic nanoparticles composed of Fe2O3 cores coated with polyethylene glycol. Laser pulses of 639 nm proved to be the optimal setting to reveal the magnetic particles, whereas 850 nm provided maximum absorption with the gold nanotubes.

Functionalizing the gold nanotubes with folate allowed the researchers to track breast cancer and melanoma cells with the lymph system, in separate attempts. Increasing the laser pulse energy from a normal 20 mJ/cm2 to 100 mJ/cm2 enabled the team to not only locate melanoma cells, but also to destroy them. At that energy level, microbubbles form, surrounding the gold nanotubes or the cells themselves; the heated bubbles disintegrate any nearby cancer cells.

“Since photoacoustics can target hemoglobin in blood vessels, it is possible to reconstruct the vasculature and microvasculature,” said the University of Missouri’s Viator. “It may be possible to use this to identify cancerous tumors, which are known to be hypervascular.”

Getting a read on retinas


For some researchers, nowhere is the vasculature more interesting than inside the eye. Acquiring high-resolution 3-D images of the retina’s microvasculature, in particular, or of the retinal pigment epithelium (RPE), could provide important insights into a number of diseases, including diabetic retinopathy and age-related macular degeneration.

Hao F. Zhang, an assistant professor at the University of Wisconsin-Milwaukee, believes that ocular imaging using photo-acoustic techniques has the greatest potential to be adopted into clinics. He and his colleagues have worked in photoacoustic microscopy for several years and have combined the technique with other optical methods, such as confocal and fluorescence microscopy and optical coherence tomography.


Figure 1. Researchers at the University of Wisconsin-Milwaukee combine spectral-domain OCT with photoacoustic optical microscopy. Schematics show the system layout (left) and the path of the optical beam to the retina and the position of the slim ultrasonic transducer (right). The two imaging subsystems are synchronized by the photoacoustic optical microscopy laser pulses detected by photodiode #1. SLD = superluminescent diode; UT = ultrasonic transducer; Pd = photodiode; FOV = field of view; PC = polarization controller. Reused with permission of the Optical Society of America.


Gentec Electro-Optics Inc   - Measure Your Laser MR
To study retinal components, Zhang’s team has combined spectral-domain OCT with photoacoustic microscopy. The group uses a 532-nm frequency-doubled Q-switched Nd:YAG laser made by Elforlight Ltd. of Daventry, UK, and an 870-nm superluminescent diode made by Inphenix Inc. of Livermore, Calif., as illumination sources. The laser was set to emit 2-ns pulses at 10 µJ each. As with normal OCT methods, the beam was split: one beam to the target retina, one to a photodiode as a reference beam. A lab-built ultrasonic transducer 1 mm in diameter was placed on the subject’s eyelid to receive the sonic signal generated by the laser pulses upon striking the retina (Figures 1 and 2).


Figure 2.
With the University of Wisconsin’s system, OCT and photoacoustic optical microscopy images are acquired simultaneously in vivo. Compare a photoacoustic optical microscopy B-scan image in pseudocolors (a) with an OCT B-scan image (b). A maximum amplitude projection image of the photoacoustic optical microscopy data set is shown in (c). Scale bar = 100 μm. HA = hyaloid artery (remnant); RPE = retinal pigment epithelium. Reused with permission of the Optical Society of America.


Hemoglobin and melanin strongly absorb light, providing contrast against the rest of blood’s components and thus providing a good basis for both functional and anatomic imaging of the retina’s vasculature and the RPE, according to Zhang’s group.

“The unique optical absorption contrast mechanism,” Zhang said of photoacoustic microscopy, “is not currently available elsewhere.”

To the clinic

Photoacoustic technologies are just beginning to be adapted into clinical settings, according to the University of Missouri’s John Viator and other researchers. They are too new to have matured into the role.

“Much of the early work in biomedical photoacoustics was done in the mid to late 1990s, and much of the technology is now becoming mature enough to be used clinically,” Viator said. “I predict an increasingly active industry using photoacoustics in the next decade.”

To some, it’s a matter of presenting a technology with which clinicians already are familiar. According to Wiendelt Steenbergen, a professor at the University of Twente in Enschede, the Netherlands, new photoacoustic technology must be integrated with already established ultrasound imaging.

Among the topics with which Steenbergen and his associates are occupied is photoacoustic mammography. Traditional x-ray mammography is well known to have problems with ionizing radiation, yet it remains the gold standard for cancer detection. Magnetic resonance imaging suffers from low specificity and high cost; ultrasound imaging alone offers too-low sensitivity; and infrared imaging does not have the penetrating power to reach most subcutaneous tumors because of light scattering.

To address the problems with all of these techniques, Steenbergen’s group developed a system a few years ago that it has dubbed the “Twente photoacoustic mammoscope.” The device uses a beam from a Q-switched Nd:YAG laser made by Paris-based Quantel operating at 1064 nm to acoustically excite breast tissue. The team members used a lab-built ultrasound detector with 590 elements to pick up the resulting sonic emissions. Figure 3 shows some resulting images.


Figure 3.
Shown are images acquired by Wiendelt Steenbergen’s group at the University of Twente via craniocaudal x-ray mammography (a) and via ultrasound (b), with each showing a large tumor with well-defined margins. The area judged to be the region of interest is outlined in the x-ray image. The contour of the breast is shown under compression in the researcher’s photoacoustic mammogram system, with the region of interest and possible location of a tumor indicated (c). The maximum intensity projections of the 3-D reconstructed photoacoustic data are shown in (d). The ring-shaped region of high intensity likely indicates the tumor rim, where blood vessels are plentiful. Reused with permission of IEEE Journal of Selected Topics in Quantum Electronics.


“Photoacoustics enables imaging optical absorption at a high resolution, even at tissue depths where optical scattering prevents high-resolution optical imaging,” Steenbergen said. To achieve significant depth, however, each laser pulse must be at least 50 µJ, which requires beam expansion so that patients’ skin isn’t at risk.

The system is undergoing clinical trials, and Steenbergen’s team has also turned toward speeding up the mammoscope’s imaging ability, gaining contrast enhancement via gold nanorods and improving the detector’s angular field of view. Steenbergen also has identified several general areas where photoacoustic technology must be improved, including quantifiability, a better selection of light sources with sufficient pulse energy to gain depth of penetration into tissue, and a better broadband ultrasound array detector with sufficient sensitivity.

A sound technology


According to the University of Arkansas’ Vladimir Zharov, photoacoustics research is being driven by improvements in “optical resolution down to the diffraction limit (200 to 250 nm), temporal resolution up to 10 to 100 µs for high-speed imaging and detection of dynamic events (e.g., moving cells), and multispectral capability for real-time multicolor cytometry.”

One possible path to resolution improvement is to update the transducer from its piezo-based origins. Günther Paltauf of Karl Franzens University of Graz in Austria and his colleagues have eschewed traditional acoustic detection for optical detection of the emitted sound waves. Although it remains the standard method for sound wave detection, piezo-based transducers lose sensitivity as their scan heads shrink, and smaller devices will be necessary to spread into more clinical use.

“We are specializing in developing detection methods for photoacoustic imaging and related image reconstruction algorithms,” he said. “A strong focus is on optical detection of ultrasound, which has several advantages compared to conventional piezoelectric detection.”

The technique developed by Paltauf’s team is based on a laser beam that is focused on the target but is left to propagate freely in a coupling liquid that surrounds the target. When a second beam triggers the photoacoustic reaction in the target, the emitted sound waves cause small phase changes in the freely propagating beam. These minute changes in phase are detected by a Mach-Zehnder interferometer. The team has used this technique to create high-resolution 3-D images of mouse hearts, human hairs and other structures (Figure 4).


Figure 4.
A group led by Günther Paltauf of Karl Franzens University of Graz used 3-D photoacoustic imaging to study mouse hearts. Shown here are four sections of one such image. RV = right ventricle; LV = left ventricle; LA = left atrium; MV = mitral valve and PM = papillary muscles. Reused with permission of the Journal of Biomedical Optics.


According to Paltauf, however, there remain limitations to purely photoacoustic techniques.

“The imaging information is somewhat limited because only optical absorption contrast can be seen,” he said. “It is therefore desirable to combine photoacoustic with other purely ultrasonic or purely optical methods to gain additional, complementary information.”

Whether photoacoustics becomes part of a multimodal imaging package or continues with breakthroughs by itself, there is no doubt that it has momentum.

“Photoacoustics has to compete with several already accepted and mature imaging modalities, such as MRI, ultrasound imaging and CT scans,” Steenbergen said. “Compared to these, photoacoustics has unique features [but] still has to reach a higher stage of sophistication to find acceptance in clinical research.”

Zharov foresees a time when photo-acoustic technology will become a mainstay, with noninvasive, rapid examination of nearly all of the body’s entire three to five liters of blood undergoing examination for single cancer cells, pathogens or other intruders with a sensitivity that is not possible with other technologies.

Published: November 2010
Glossary
flow cytometry
Flow cytometry is a powerful technique used in biology and medicine for the quantitative analysis of the physical and chemical characteristics of cells and particles suspended in a fluid. The method allows for the rapid measurement of multiple parameters simultaneously on a cell-by-cell basis. It is widely used in various fields, including immunology, microbiology, hematology, and cancer research. Here are the key components and features of flow cytometry: Sample preparation: Cells or...
fluorescence microscopy
Fluorescence microscopy is a specialized optical imaging technique used in biology, chemistry, and materials science to visualize and study specimens that exhibit fluorescence. Fluorescence is the phenomenon where a substance absorbs light at one wavelength and emits light at a longer wavelength. In fluorescence microscopy, fluorescent dyes or proteins are used to label specific structures or molecules within a sample. The basic principles of fluorescence microscopy involve illuminating the...
nanoparticle
A small object that behaves as a whole unit or entity in terms of it's transport and it's properties, as opposed to an individual molecule which on it's own is not considered a nanoparticle.. Nanoparticles range between 100 and 2500 nanometers in diameter.
noise
The unwanted and unpredictable fluctuations that distort a received signal and hence tend to obscure the desired message. Noise disturbances, which may be generated in the devices of a communications system or which may enter the system from the outside, limit the range of the system and place requirements on the signal power necessary to ensure good reception.
photoreactive agent
Participates in a reaction only in the presence of light and radiant energy. Besides 3D printing, photoreactive agents also have an application in light therapy. By absorbing light, photoreactive agents will destroy abnormal tissue either directly or by preventing nutrients from reaching it.
retina
1. The photosensitive membrane on the inside of the human eye. 2. A scanning mechanism in optical character generation.
Basic ScienceBiophotonicscancer tumorscarboncoherence tomographyFeaturesflow cytometryfluorescence microscopygold nanotubeshemodynamicshemoglobinImagingLight Sourcesmagnetic nanoparticlesmelanomametastasisMicroscopynanoparticlenoiseOCTocular imagingOpticsphotoacoustic technologyphotoreactive agentretinaSensors & Detectorsskinsound wavesultrasoundvasculatureLEDs

We use cookies to improve user experience and analyze our website traffic as stated in our Privacy Policy. By using this website, you agree to the use of cookies unless you have disabled them.