Register
Sign In
Suppliers
Products
Categories
Handbook
Dictionary
Careers
Resources
Photonics Spectra
BioPhotonics
Vision Spectra
Virtual Events & Summits
Educational Institutions
Add/Update Your Listing
Exhibitor Listing Portal
Become an Exhibitor
Buyers' Guide Print Edition
Marketplace Help
Subscribe
Advertise
Suppliers
Products
Categories
Handbook
Dictionary
Careers
Resources
Photonics Spectra
BioPhotonics
Vision Spectra
Virtual Events & Summits
Educational Institutions
Add/Update Your Listing
Exhibitor Listing Portal
Become an Exhibitor
Buyers' Guide Print Edition
Marketplace Help
Register
Sign In
Photonics Marketplace
Suppliers
Products
Handbook
Institutions
Dictionary
Show Filters
Hide Filters
Products by Category
< All Categories
< Spectroscopy
Spectrometers
Benchtop
Portable
Applications
Biomedical/Medical
Defense
Environmental Monitoring
Light Characterization
Materials Identification
Other
Scientific Research
Semiconductor
Measurement Techniques
Absorption
Emission
Fluorescence
FTIR
Inelastic Scattering
Mass Spectrometry
Other
Raman
Reflectance and Transmission
Excitation Wavelength (nm)
-
Spectral Range (nm)
-
Max. Resolution (nm)
-
Pixel Count (total pixels)
-
Width
Dimensions
-
mm
cm
Length
Dimensions
-
mm
cm
Height
Dimensions
-
mm
cm
Weight (kg)
-
Key Suppliers
OZ Optics Limited
Thorlabs Inc.
Hamamatsu Corporation
Andor Technology
B&W Tek LLC
Edinburgh Instruments Ltd.
DRS Daylight Solutions Inc.
Admesy BV
Telops Inc.
Headwall Photonics Inc.
Optronic Laboratories LLC
Teledyne Princeton Instruments
Avantes BV
LightMachinery Inc.
Ocean Optics
13 products
Spectrometers
Clear All Filters x
semiconductor lasers x
Spectroscopy x
Spectrometers x
Optical Spectrum Analyzer
Thorlabs Inc.
Type:
Benchtop
Measurement Techniques:
Other
Spectral Range (nm):
1000 - 5600
Width:
541mm
Length:
532.6mm
Height:
224.1mm
Weight (kg):
26.5
Free-Space Window:
Uncoated CaF2
Input Power (Max.):
10 mW (10 dBm)
Operating Temperature:
10 °C to 40 °C
AQ6374E Wide Wavelength Range Optical Spectrum Analyzer
Yokogawa Test&Measurement
Type:
Benchtop
Measurement Techniques:
Absorption,Emission,Fluorescence,FTIR,Mass Spectrometry,Reflectance and Transmission,Inelastic Scattering,Raman,Other
Spectral Range (nm):
350 - 1750
Max. Resolution (nm):
0.05
Pixel Count (total pixels):
786432
Width:
426mm
Length:
459mm
Built-In Cut Filter:
High order diffracted light
Close-In Dynamic Range:
60 dB (λPK ±1 nm)
Free Space Input:
Can use SM or MM fibers
AQ6370E Telecom Optical Spectrum Analyzer
Yokogawa Test&Measurement
Type:
Benchtop
Measurement Techniques:
Absorption,Emission,Fluorescence,FTIR,Mass Spectrometry,Reflectance and Transmission,Inelastic Scattering,Raman,Other
Spectral Range (nm):
600 - 1700
Max. Resolution (nm):
0.02
Pixel Count (total pixels):
786432
Width:
426mm
Length:
459mm
Close-In Dynamic Range:
78 dB
Free Space Input:
Can use SM or MM fibers
Level Range:
+20 to -90 dBm
AQ6377 Five Micron Optical Spectrum Analyzer
Yokogawa Test&Measurement
Type:
Benchtop
Measurement Techniques:
Absorption,Emission,Fluorescence,FTIR,Mass Spectrometry,Reflectance and Transmission,Inelastic Scattering,Raman,Other
Spectral Range (nm):
1900 - 5500
Max. Resolution (nm):
0.2
Pixel Count (total pixels):
480000
Width:
426mm
Length:
459mm
Built-In Cut Filter:
High order diffracted light
Close-In Dynamic Range:
50 dB
Free Space Input:
Can use SM or MM fibers
enVISion
Magnitude Instruments
Type:
Benchtop
Measurement Techniques:
Absorption,Emission,Fluorescence,Reflectance and Transmission,Other
Spectral Range (nm):
300 - 2500
Max. Resolution (nm):
1
Width:
116cm
Length:
66cm
Height:
33cm
Detection Limit:
10^-7 Absorbance Change
Excitation Rep-Rate:
8 Hz - 19 kHz
Sample Compartment Size:
25 cm × 25 cm
enVISTA
Magnitude Instruments
Type:
Benchtop
Measurement Techniques:
Absorption,Emission,Fluorescence,Reflectance and Transmission,Other
Excitation Wavelength (nm):
0
Spectral Range (nm):
300 - 1050
Max. Resolution (nm):
1
Width:
67.3cm
Length:
59cm
Detection Limit:
10^-7 Absorbance Change
Excitation Rep-Rate:
8 Hz - 19 kHz
Sample Compartment Size:
25 cm × 25 cm
inspIRe
Magnitude Instruments
Type:
Benchtop
Measurement Techniques:
Absorption,Emission,Fluorescence,Reflectance and Transmission
Spectral Range (nm):
2000 - 10000
Width:
116cm
Length:
66cm
Height:
33cm
Weight (kg):
90
Detection Limit:
10^-7 Absorbance Change
Excitation Rep-Rate:
8 Hz - 19 kHz
Sample Compartment Size:
25 cm × 25 cm
HELIOS
Ultrafast Systems
Type:
Benchtop
Measurement Techniques:
Absorption
Spectral Range (nm):
320 - 2400
Max. Resolution (nm):
2
Pixel Count (total pixels):
2048
Width:
457mm
Length:
915mm
Probe reference:
optional
Pump beam diameter:
≤ 9 mm
Sample area:
225 mm × 250 mm
HyperFlux™ PRO Plus
Tornado Spectral Systems
Type:
Benchtop
Measurement Techniques:
Raman
Excitation Wavelength (nm):
785
Spectral Range (nm):
798 - 1060
Max. Resolution (nm):
0.38
Width:
46.7cm
Length:
13.7cm
Laser Power:
20 mW up to 495 mW
TERA K15
Menlo Systems Inc.
Type:
Portable
Measurement Techniques:
Absorption,Reflectance and Transmission
Width:
900mm
Length:
600mm
Height:
200mm
Weight (kg):
34
Dynamic range:
>90 dB (typ. 95 dB)
Laser ports:
1560 nm, alternat. 780 nm
Laser repetition rate:
100 MHz
HyperFlux™ U1
Tornado Spectral Systems
Type:
Benchtop
Measurement Techniques:
Raman
Excitation Wavelength (nm):
785
Spectral Range (nm):
749 - 1024
Max. Resolution (nm):
0.38
Width:
50.8cm
Length:
29.8cm
Detector:
Andor iDUS DU416A-LCD-DD
Mini PL/Raman
Photon Systems
Type:
Benchtop
Measurement Techniques:
Fluorescence,Raman,Other
Excitation Wavelength (nm):
224.3
Spectral Range (nm):
180 - 800
Max. Resolution (nm):
0.2
Width:
150mm
Length:
360mm
FluoTime 300
PicoQuant GmbH
Type:
Benchtop
Measurement Techniques:
Emission,Fluorescence,Other
Spectral Range (nm):
200 - 910
Max. Resolution (nm):
0.1
Width:
900mm
Length:
1100mm
Height:
400mm
Spectrometers Products
Need Help?
Explore Our Content
News
Features
Latest Products
Webinars
White Papers
All Things Photonics Podcast
Videos
Our Summits & Conferences
Industry Events
Bookstore
Join Our Community
Subscribe
Advertise
Become a member
Sign in
Contribute a Feature
Suggest a Webinar
Submit a Press Release
Mobile Apps
About Us
Our Company
Our Publications
Contact Us
Career Opportunities
Teddi C. Laurin Scholarship
Terms & Conditions
Privacy Policy
California Consumer Privacy Act (CCPA)
©2024 Photonics Media
100 West St.
Pittsfield, MA, 01201 USA
[email protected]
We use cookies to improve user experience and analyze our website traffic as stated in our
Privacy Policy
. By using this website, you agree to the use of
cookies
unless you have disabled them.